Diafon Cables

   CONSTRUCTION

 

Conder (DT13) :7 x 0,22 mm cu
Insulation (DT13) :PVC Compound
Core Identification (Screened DT13) :Coloured Code
Lay-Up (Screened DT13) :Pairs laid up in
layers of optimum picth
Outer Sheath (DT13) :PVC Compound
Sheath Colour (DT13) :Orange

 

   APPLICATION

 

Used in structure installations, interrior communications and sound systems an diafon systems.

 

   TECHNICAL DATAS
            
 
Test Voltage : 1500 V
Working Temperature : -30 °C ~+70 °C
Min.Bending Radius : 10 x Cable Diameter
Insulation Resistance : >20 M Ω km 
Capatitance : 100 nF/km
Working Voltage : 250 V
Num. of Cores x Cross Section (mm²) Approx. Outher Dimeter (mm) Copper Weight (kg/km) Approx.Cable Weight (kg/km)
4 x 0,22 3,60 7,70 21,00
6 x 0,22 4,60 11,33 33,10
8 x 0,22 5,20 15,23 40,50
10 x 0,22 6,00 19,05 48,70
12 x 0,22 6,30 22,85 57,00
13 x 0,22 6,40 24,75 61,15
4 x 0,25 4,30 9,60 26,2
6 x 0,25 5,00 13,38 33,50
8 x 0,25 6,20 19,20 49,2
12 x 0,25 7 28,8 67
13 x 0,25 7,10 31,2 71,15